Functional Semi-Automated Segmentation of Renal DCE-MRI Sequences - CentraleSupélec Accéder directement au contenu
Communication Dans Un Congrès Année : 2008

Functional Semi-Automated Segmentation of Renal DCE-MRI Sequences

Résumé

In dynamic contrast-enhanced magnetic resonance imaging (DCE- MRI), segmentation of internal kidney structures is essential for functional evaluation. Manual morphological segmentation of cortex, medulla and cavities remains difficult and time- consuming especially because the different renal compartments are hard to distinguish on a single image. We propose to test a semi-automated method to segment internal kidney structures from a DCE-MRI registered sequence. As the temporal intensity evolution is different in each of the three kidney compartments, pixels are sorted according to their time- intensity curves using a k-means partitioning algorithm. No ground truth is available to evaluate resulting segmentations so a manual segmentation by a radiologist is chosen as a reference. We first evaluate some similarity criteria between the functional segmentations and this reference. The same measures are then computed between another manual segmentation and the reference. Results are similar for the two types of comparisons.
Fichier principal
Vignette du fichier
ICASSP.pdf (114.96 Ko) Télécharger le fichier
Origine : Fichiers éditeurs autorisés sur une archive ouverte
Loading...

Dates et versions

hal-00276131 , version 1 (28-04-2008)

Identifiants

  • HAL Id : hal-00276131 , version 1

Citer

Béatrice Chevaillier, Yannick Ponvianne, Jean-Luc Collette, Damien Mandry, Michel Claudon, et al.. Functional Semi-Automated Segmentation of Renal DCE-MRI Sequences. ICASSP 2008, Apr 2008, Las Vegas, United States. pp.525-528. ⟨hal-00276131⟩
71 Consultations
561 Téléchargements

Partager

Gmail Facebook X LinkedIn More