Sensor-fault Detection and Isolation using Interval Observers - CentraleSupélec Accéder directement au contenu
Communication Dans Un Congrès Année : 2013

Sensor-fault Detection and Isolation using Interval Observers

Résumé

This paper proposes an interval observer-based sensor fault detection and isolation (FDI) approach for closed-loop systems. In the proposed approach, residuals are defined in such a way that their components are independent of each other at the time instant after fault occurrence, namely kf +1, where kf denotes the fault occurrence time instant. In this way, it is guaranteed that at kf +1 the changes in each component of the residuals are only related to the fault in the corresponding sensor. By detecting the threshold violation of the corresponding residual interval components, the proposed approach can detect and isolate sensor faults at the same time instant. At the end of this paper, a numerical example is used to present the effectiveness of the proposed approach.

Dates et versions

hal-00918188 , version 1 (13-12-2013)

Identifiants

Citer

Feng Xu, Vicenc Puig, Carlos Ocampo-Martinez, Florin Stoican, Sorin Olaru. Sensor-fault Detection and Isolation using Interval Observers. Systol 2013 - 2nd International Conference on Control and Fault-Tolerant Systems, Oct 2013, Nice, France. pp.55-60, ⟨10.1109/SysTol.2013.6693860⟩. ⟨hal-00918188⟩
214 Consultations
0 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More