F. Baccino, M. Marinelli, S. Massucco, and F. Silvestro, Low voltage microgrid under islanded operation: Control strategies and experimental tests, 8th Mediterranean Conference on, pp.1-3, 2012.

Y. Zoka, R. Tonoda, Y. Mashima, Y. Sasaki, and N. Yorino, An ondemand control system for demand and supply control of small independent power grids, pp.4-7, 2012.

W. Tian, Jinghan He

Z. Bo, Simulation of vehicle-to-grid (V2G) on power system frequency control, IEEE, vol.3, issue.1, pp.21-24, 2012.

Y. Ota, H. Taniguchi, T. Nakajima, K. M. Liyanage, J. Baba et al., Autonomous distributed V2G (vehicle-to-grid) considering charging request and battery condition, IEEE PES, vol.6, issue.1, pp.11-13, 2010.

K. Shimizu, T. Masuta, Y. Ota, and A. Yokoyama, Load Frequency Control in Power System Using Vehicle-to-Grid System Considering the Customer Convenience of Electric Vehicles, Proc. 2010 International Conference on Power System Technology

K. M. Liyanage, A. Yokoyama, Y. Ota, T. Nakajima, and H. Taniguchi, Impacts of Communication Delay on the Performance of a Control Scheme to Minimize Power Fluctuations Introduced by Renewable Generation under Varying V2G Vehicle Pool Size, Proc. 2010 IEEE SmartGridComm

A. Brooks, E. Lu, D. Reicher, C. Spirakis, and B. Weihl, Demand Dispatch, IEEE Power & Engineering Magazine, vol.8, issue.3, pp.20-29, 2010.

P. M. Almeida, J. A. Lopes, F. J. Soares, and M. H. Vasconcelos, Automatic Generation Control operation with electric vehicles, Bulk Power System Dynamics and Control (iREP) -VIII (iREP), 2010 iREP Symposium, vol.7, pp.1-6, 2010.

W. Su and M. Chow, Performance evaluation of an EDA-based large-scale plug-in hybrid electric vehicle charging algorithm, IEEE Trans. Smart Grid, vol.3, issue.1, pp.308-315, 2012.

Y. Cao, S. Tang, C. Li, P. Zhang, Y. Tan et al., An optimized EV charging model considering TOU price and SOC curve, IEEE Trans. Smart Grid, vol.3, issue.1, pp.388-393, 2012.

. Ministry and . Power, Smart Grid Vision and Roadmap for, vol.12, 2013.

S. Vachirasricirikul and I. Ngamroo, Robust LFC in a Smart Grid With Wind Power Penetration by Coordinated V2G Control and Frequency Controller, IEEE Transactions on, vol.5, issue.1, p.371, 2014.

A. Yokoyama, Smarter grid I, IEEJ J, vol.30, issue.2, pp.94-97, 2010.

A. Yokoyama, Smarter grid II, IEEJ J, vol.30, issue.3, pp.163-167, 2010.

M. Takagi, K. Yamaji, and H. Yamamoto, Power system stabilization by charging power management of plug-in hybrid electric vehicles with LFC signal, Proc. 2009 IEEE Veh. Power Propulsion Conf, pp.822-826

Y. Ota, H. Taniguchi, T. Nakajima, K. M. Liyanage, and A. Yokoyama, An autonomous distributed vehicle-to-grid control of grid-connected electric vehicle, Proc. 2009 IEEE Ind, pp.414-418

T. Masuta and A. Yokoyama, Supplementary load frequency control by use of a number of both electric vehicles and heat pump water heaters, IEEE Trans. Smart Grid, vol.3, issue.3, pp.1253-1262, 2012.

Y. Ota, H. Taniguchi, T. Nakajima, K. M. Liyanage, J. Baba et al., Autonomous distributed V2G (vehicle-to-grid) satisfying scheduled charging, IEEE Trans. Smart Grid, vol.3, issue.1, pp.559-564, 2012.

H. Yogesh-krishan-bhateshvar, H. Mathur, . Siguerdidjane-&-surekha, and . Bhanot, Frequency Stabilization for Multi-area Thermal-Hydro Power System Using Genetic Algorithm-optimized Fuzzy Logic Controller in Deregulated Environment, Electric Power Components and Systems, vol.43, pp.146-156, 2015.

Y. K. Bhateshvar, H. D. Mathur, and H. Siguerdidjane, Study of Impact of Wind Power Generating System Integration on Frequency Stabilization in Multi-area Power System with Fuzzy Logic Controller in Deregulated Environment, vol.9, pp.7-21, 2015.

P. Bhatt, R. Roy, and S. P. Ghoshal, Optimized multi area AGC simulation in restructured power systems, Int. J. Elect. Power Energy Syst, vol.32, issue.4, pp.311-322, 2010.

S. Panda and N. K. Yegireddy, Automatic generation control of multiarea power system using multi-objective non-dominated sorting genetic algorithm-II, Int. J. Elect. Power Energy Syst, vol.53, pp.54-63, 2013.

E. Çam and K. I. , Load frequency control in two area power systems using fuzzy logic controller, Energy Convers. Manag, vol.46, issue.2, pp.233-243, 2005.

W. Tan, H. Zhang, and M. Yu, Decentralized load frequency control in deregulated environments, International Journal of Electrical Power & Energy Systems, vol.41, issue.1, pp.16-26, 2012.

B. Boukhezzar and H. Siguerdidjane, Nonlinear control with wind estimation of a DFIG variable speed wind turbine for power capture optimization, Energy Conversion and Management, vol.50, issue.4, pp.885-892, 2009.
URL : https://hal.archives-ouvertes.fr/hal-00418145

, A. Parameters of Hydro Thermal System Investigated: Pr1= Pr2=2000MW

B. , Parameters of Wind Turbine Investigated: H=4.64

C. , Parameters of V2GSystem Investigated: Te=1

/. Pmax=200, , 1000.