Echo Response of Faults in Transmission Lines: Models and Limitations to Fault Detection - CentraleSupélec Accéder directement au contenu
Article Dans Une Revue IEEE Transactions on Microwave Theory and Techniques Année : 2016

Echo Response of Faults in Transmission Lines: Models and Limitations to Fault Detection

Résumé

This paper introduces models of the time-domain echoes generated by faults in transmission lines excited by test signals, e.g., as in applications of time-domain reflectometry. Faults here considered include local modifications of the propagation characteristics of a transmission line. It is shown that the response of faults are strongly dispersive in nature, which implies that the peak of their echo is far from providing an accurate measure of the severity of the fault, as it heavily depends on the frequency content of the test signal, as well as on the length of the fault. It is argued that fault detection in transmission lines is an ill-posed problem that requires a priori knowledge on the fault itself. These results are important for applications of time-domain reflectometry methods, particularly for early-warning monitoring of potentially critical faults from their onset, since it is shown that echoes from faults tested at relatively low frequencies can lead to underestimate their actual severity.
Fichier principal
Vignette du fichier
MTT2013-soft_faults_rev3.pdf (664.46 Ko) Télécharger le fichier
Origine : Fichiers produits par l'(les) auteur(s)
Loading...

Dates et versions

hal-01352701 , version 1 (09-08-2016)

Identifiants

Citer

Andréa Cozza, Lionel Pichon. Echo Response of Faults in Transmission Lines: Models and Limitations to Fault Detection. IEEE Transactions on Microwave Theory and Techniques, 2016, 64 (12), pp.4155 - 4164. ⟨10.1109/TMTT.2016.2608774⟩. ⟨hal-01352701⟩
120 Consultations
739 Téléchargements

Altmetric

Partager