A Statistical Study of DORT Method for Locating Soft Faults in Complex Wire Networks - CentraleSupélec Accéder directement au contenu
Article Dans Une Revue IEEE Transactions on Magnetics Année : 2018

A Statistical Study of DORT Method for Locating Soft Faults in Complex Wire Networks

Résumé

Decomposition of the time-reversal (TR) operator (DORT), a recently applied TR method to transmission lines, has proven to be effective in detecting and locating soft faults in complex wire networks. In this paper, we will propose a fault location criterion which will form a later basis for a statistical study investigating the influence of several parameters, namely, the number of testing ports and the position of the fault, on the performance of DORT technique. Notably, this would allow a closer inspection of the method's practicability for future implementation in real-life networks. Index Terms— Complex wire networks, decomposition of the time-reversal (TR) operator (DORT) method, soft fault location, statistical study.
Fichier principal
Vignette du fichier
08107704.pdf (816.66 Ko) Télécharger le fichier
Origine : Fichiers produits par l'(les) auteur(s)
Loading...

Dates et versions

hal-01639241 , version 1 (20-11-2017)

Identifiants

Citer

Moussa Kafal, Jaume Benoit, Andréa Cozza, Lionel Pichon. A Statistical Study of DORT Method for Locating Soft Faults in Complex Wire Networks. IEEE Transactions on Magnetics, 2018, 54 (3), pp.8700304. ⟨10.1109/TMAG.2017.2765463⟩. ⟨hal-01639241⟩
406 Consultations
236 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More