Condition-based probabilistic safety assessment of a spontaneous steam generator tube rupture accident scenario - CentraleSupélec Access content directly
Journal Articles Nuclear Engineering and Design Year : 2018

Condition-based probabilistic safety assessment of a spontaneous steam generator tube rupture accident scenario

Abstract

Condition-Based Probabilistic Safety Assessment (CB-PSA) makes use of the information made available during operation by sensors and/or inspections on the state of components and systems. This allows specializing the PSA to the conditions of the components and systems, reducing the uncertainty on the risk measures quantified. In this paper, we demonstrate the CB-PSA with reference to a spontaneous Steam Generator Tube Rupture (SGTR) accident scenario in a Pressurized Water Reactor (PWR). Results show that the updated risk measures are capable of reflecting the actual state of the SG in the tailored risk evaluation.
Fichier principal
Vignette du fichier
2018_Condition-based-probabilistic-safety-assessment-of-a-spontaneous-steam-generator-tube-rupture-accident-scenario.pdf (826.7 Ko) Télécharger le fichier
Origin : Files produced by the author(s)
Loading...

Dates and versions

hal-01786565 , version 1 (19-03-2020)

Identifiers

Cite

Francesco Di Maio, Federico Antonello, Enrico Zio. Condition-based probabilistic safety assessment of a spontaneous steam generator tube rupture accident scenario. Nuclear Engineering and Design, 2018, 326, pp.41 - 54. ⟨10.1016/j.nucengdes.2017.10.020⟩. ⟨hal-01786565⟩