W. D. Rooney, G. Johnson, and X. Li, Magnetic field and tissue dependencies of human brain longitudinal 1H2O relaxation in vivo, Magn Reson Med, vol.57, issue.2, pp.308-318, 2007.

J. T. Vaughan, M. Garwood, and C. M. Collins, 4T: RF power, homogeneity, and signal-tonoise comparison in head images, Magn Reson Med, vol.46, issue.1, pp.24-30, 2001.

C. Kang, C. Park, and J. Han, Imaging and analysis of lenticulostriate arteries using 7.0-Tesla magnetic resonance angiography, Magn Reson Med, vol.61, issue.1, pp.136-144, 2009.

S. Schmitter, M. Bock, S. Johst, E. J. Auerbach, K. U?urbil et al., Contrast enhancement in TOF cerebral angiography at 7 T using saturation and MT pulses under SAR constraints: impact of VERSE and sparse pulses, Magn Reson Med, vol.68, issue.1, pp.188-197, 2012.

C. Von-morze, D. Xu, and D. D. Purcell, Intracranial time-of-flight MR angiography at 7T with comparison to 3T, J Magn Reson Imaging JMRI, vol.26, issue.4, pp.900-904, 2007.

J. T. Heverhagen, E. Bourekas, S. Sammet, M. V. Knopp, and P. Schmalbrock, Time-of-flight magnetic resonance angiography at 7 Tesla, Invest Radiol, vol.43, issue.8, pp.568-573, 2008.

S. Johst, K. H. Wrede, M. E. Ladd, and S. Maderwald, Time-of-flight magnetic resonance angiography at 7 T using venous saturation pulses with reduced flip angles, Invest Radiol, vol.47, issue.8, pp.445-450, 2012.

C. Mönninghoff, S. Maderwald, and J. M. Theysohn, Evaluation of intracranial aneurysms with 7 T versus 1.5 T time-of-flight MR angiography -initial experience, ROFO Fortschr Geb Rontgenstr Nuklearmed, vol.181, issue.1, pp.16-23, 2009.

J. Zwanenburg, J. Hendrikse, T. Takahara, F. Visser, and P. R. Luijten, MR angiography of the cerebral perforating arteries with magnetization prepared anatomical reference at 7 T: comparison with time-of-flight, J Magn Reson Imaging JMRI, vol.28, issue.6, pp.1519-1526, 2008.

M. K. Liem, J. Van-der-grond, and M. J. Versluis, Lenticulostriate arterial lumina are normal in cerebral autosomal-dominant arteriopathy with subcortical infarcts and leukoencephalopathy: a high-field in vivo MRI study, Stroke, vol.41, issue.12, pp.2812-2816, 2010.

C. Grochowski and G. Sta?kiewicz, Ultra high field TOF-MRA: A method to visualize small cerebral vessels. 7 T TOF-MRA sequence parameters on different MRI scanners -Literature review, Neurol Neurochir Pol, vol.51, issue.5, pp.411-418, 2017.

S. Saekho, C. Yip, D. C. Noll, F. E. Boada, and V. A. Stenger, Fast-kz three-dimensional tailored radiofrequency pulse for reduced B1 inhomogeneity, Magn Reson Med, vol.55, issue.4, pp.719-724, 2006.

K. Setsompop, L. L. Wald, and V. Alagappan, Parallel RF transmission with eight channels at 3 Tesla, Magn Reson Med, vol.56, issue.5, pp.1163-1171, 2006.

S. Schmitter, X. Wu, and E. J. Auerbach, Seven-tesla time-of-flight angiography using a 16-channel parallel transmit system with power-constrained 3-dimensional spoke radiofrequency pulse design, Invest Radiol, vol.49, issue.5, pp.314-325, 2014.

S. Kim and D. L. Parker, Time-of-Flight Angiography, Magnetic Resonance Angiography, vol.2012, pp.39-50

D. L. Parker, C. Yuan, and D. D. Blatter, MR angiography by multiple thin slab 3D acquisition, Magn Reson Med, vol.17, issue.2, pp.434-451, 1991.

X. Ding, J. A. Tkach, P. R. Ruggieri, and T. J. Masaryk, Sequential three-dimensional time-of-flight MR angiography of the carotid arteries: value of variable excitation and postprocessing in reducing venetian blind artifact, Am J Roentgenol, vol.163, issue.3, pp.683-688, 1994.

D. Purdy, G. Cadena, and G. Laub, The design of variable tip angle slab selection (TONE) pulses for improved 3-D MR angiography, p.882, 1992.

P. Hardy, M. Zelch, and G. Lammert, Improved uniformity of vessel contrast in 3D (volume) MRA, p.3110, 1992.

J. Tkach, T. Masaryk, and P. Rugieri, Use of tilted optimized nonsaturating excitation (TONE) rfpulses and MTC to improve the quality of MR angiograms of the carotid bifurcaton, p.3905, 1992.

D. Atkinson, M. Brant-zawadzki, G. G. Purdy, D. Laub, and G. , Improved MR angiography: magnetization transfer suppression with variable flip angle excitation and increased resolution, Radiology, vol.190, issue.3, pp.890-894, 1994.

T. Nägele, U. Klose, W. Grodd, D. Petersen, and J. Tintera, The effects of linearly increasing flip angles on 3D inflow MR angiography, Magn Reson Med, vol.31, issue.5, pp.561-566, 1994.

A. Priatna and C. B. Paschal, Variable angle uniform signal excitation (VUSE) for three dimensional time-of-flight MR angiography, J Magn Reson Imaging, vol.5, issue.4, pp.421-427, 1995.

J. L. Friedli, C. B. Paschal, J. E. Loyd, and S. S. Halliburton, Quantitative 3D VUSE pulmonary MRA, Magn Reson Imaging, vol.17, issue.3, pp.363-370, 1999.
DOI : 10.1016/s0730-725x(98)00177-5

N. Thomas, K. Uwe, G. Wolfgang, N. Voigt-karsten, and . Fridtjof, Nonlinear excitation profiles for three-dimensional inflow MR angiography, J Magn Reson Imaging, vol.5, issue.4, pp.416-420, 1995.

G. Saïb, V. Gras, and F. Mauconduit, Double-Spoke Slab-Selective Ramp Pulse Design for UHF TOF MR Angiography, In Proc. Intl. Soc. Mag. Reson. Med, vol.25, 2017.

M. Drangova and N. J. Pelc, Artifacts and signal loss due to flow in the presence of B(o) inhomogeneity, Magn Reson Med, vol.35, issue.1, pp.126-130, 1996.

G. Mair, Lack of flow on time-of-flight MR angiography does not always indicate occlusion, BJRcase Rep, vol.2, issue.1, p.20150187, 2015.

D. L. Parker, K. C. Goodrich, and J. A. Roberts, The need for phase-encoding flow compensation in high-resolution intracranial magnetic resonance angiography, J Magn Reson Imaging JMRI, vol.18, issue.1, pp.121-127, 2003.

S. Schmitter, S. Johst, M. Bock, K. Ugurbil, and P. F. Van-de-moortele, Implementing VERSE for Time of Flight RF Pulses at 7Tesla: Methodological Considerations, Proc. Intl. Soc. Mag. Reson. Med, vol.18, p.4424, 2010.

W. Grissom, C. Yip, Z. Zhang, V. A. Stenger, J. A. Fessler et al., Spatial domain method for the design of RF pulses in multicoil parallel excitation, Magn Reson Med, vol.56, issue.3, pp.620-629, 2006.

V. Gras, M. Luong, A. Amadon, and N. Boulant, Joint design of kT-points trajectories and RF pulses under explicit SAR and power constraints in the large flip angle regime, J Magn Reson, vol.261, pp.181-189, 1997.

W. A. Grissom, M. Khalighi, L. I. Sacolick, B. K. Rutt, and M. W. Vogel, Small-tip-angle spokes pulse design using interleaved greedy and local optimization methods, Magn Reson Med, vol.68, issue.5, pp.1553-1562, 2012.
DOI : 10.1002/mrm.24165

URL : http://europepmc.org/articles/pmc3703849?pdf=render

K. Setsompop, L. L. Wald, V. Alagappan, B. A. Gagoski, and E. Adalsteinsson, Magnitude least squares optimization for parallel radio frequency excitation design demonstrated at 7 Tesla with eight channels, Magn Reson Med, vol.59, issue.4, pp.908-915, 2008.
DOI : 10.1002/mrm.21513

URL : https://onlinelibrary.wiley.com/doi/pdf/10.1002/mrm.21513

I. A. Hoyos, P. Weiss, A. Massire, A. Amadon, and N. Boulant, On Variant Strategies To Solve The Magnitude Least Squares Optimization Problem In Parallel Transmission Pulse Design And Under Strict SAR And Power Constraints. ArXiv13091567 Phys, 2013.
URL : https://hal.archives-ouvertes.fr/hal-00858823

B. Guérin, K. Setsompop, H. Ye, B. A. Poser, A. V. Stenger et al., Design of parallel transmission pulses for simultaneous multislice with explicit control for peak power and local specific absorption rate, Magn Reson Med, vol.73, issue.5, pp.1946-1953, 2015.

L. Dupas, A. Massire, A. Amadon, A. Vignaud, and N. Boulant, Two-spoke placement optimization under explicit specific absorption rate and power constraints in parallel transmission at ultra-high field, J Magn Reson, vol.255, pp.59-67, 2015.
DOI : 10.1016/j.jmr.2015.03.013

URL : https://hal.archives-ouvertes.fr/hal-01414355

G. Saïb, V. Gras, and F. Mauconduit, kT-spokes: combining kT-points with spokes to ease ramp pulse design for TOF slab selection with parallel transmission at 7T, Proc. Intl, vol.26, 2018.

, International Electrotechnical Commission. International standard, medical electrical equipment. Part 2. Particular requirements for the safety of magnetic resonance equipment for medical diagnosis, IEC, 2010.

V. Gras, A. Vignaud, A. Amadon, F. Mauconduit, L. Bihan et al., New method to characterize and correct with sub-µs precision gradient delays in bipolar multispoke RF pulses

, Magn Reson Med, vol.78, issue.6, pp.2194-2202, 2017.

G. Saïb, R. Tomi-tricot, and V. Gras, Z-segmentation of a transmit array head coil improves RF ramp pulse design at 7T, Proc. Intl, vol.26, 2018.

V. L. Yarnykh, Actual flip-angle imaging in the pulsed steady state: a method for rapid threedimensional mapping of the transmitted radiofrequency field, Magn Reson Med, vol.57, issue.1, pp.192-200, 2007.

H. Fautz, M. W. Vogel, P. Gross, A. B. Kerr, and Y. Zhu, B1 mapping of coil arrays for parallel transmission, p.1247, 2008.

A. Amadon, M. A. Cloos, N. Boulant, M. Hang, C. J. Wiggins et al., Validation of a very fast B1-mapping sequence for parallel transmission on a human brain at 7T, p.3358, 2012.

D. O. Brunner and K. P. Pruessmann, B1(+) interferometry for the calibration of RF transmitter arrays, Magn Reson Med, vol.61, issue.6, pp.1480-1488, 2009.

S. M. Smith, Fast robust automated brain extraction, Hum Brain Mapp, vol.17, issue.3, pp.143-155, 2002.

M. A. Cloos, N. Boulant, and M. Luong, kT-points: Short three-dimensional tailored RF pulses for flip-angle homogenization over an extended volume, Magn Reson Med, vol.67, issue.1, pp.72-80, 2012.

K. Setsompop, V. Alagappan, and B. A. Gagoski, Broadband slab selection with B 1+ mitigation at 7T via parallel spectral-spatial excitation, Magn Reson Med, vol.61, issue.2, pp.493-500, 2009.

B. Guérin, J. Stockmann, M. Baboli, A. Torrado-carvajal, A. V. Stenger et al., Robust timeshifted spoke pulse design in the presence of large B0 variations with simultaneous mitigation for through-plane dephasing, B1+ effects and the specific absorption rate using parallel transmission, Magn Reson Med, vol.76, issue.2, pp.540-554, 2016.

N. Chen and A. M. Wyrwicz, Removal of intravoxel dephasing artifact in gradient-echo images using a field-map based RF refocusing technique, Magn Reson Med, vol.42, issue.4, pp.807-812, 1999.

J. Eun-kee, P. Dennis, L. , T. Jay, S. et al., Reduction of flow-related signal loss in flow-compensated 3D TOF MR angiography, using variable echo time (3D TOF-VTE), Magn Reson Med, vol.48, issue.4, pp.667-676, 2002.

W. H. Bouvy, L. J. Geurts, and H. J. Kuijf, Assessment of blood flow velocity and pulsatility in cerebral perforating arteries with 7-T quantitative flow MRI, Nmr Biomed, vol.29, issue.9, pp.1295-1304, 2016.

R. Aaslid, T. M. Markwalder, and H. Nornes, Noninvasive transcranial Doppler ultrasound recording of flow velocity in basal cerebral arteries, J Neurosurg, vol.57, issue.6, pp.769-774, 1982.

L. Zarrinkoob, K. Ambarki, A. Wahlin, R. Birgander, A. Eklund et al., Blood flow distribution in cerebral arteries, J Cereb Blood Flow Metab, vol.35, issue.4, pp.648-654, 2015.

Z. Zhang, X. Deng, and D. Weng, Segmented TOF at 7T MRI: Technique and clinical applications, Magn Reson Imaging, vol.33, issue.9, 2015.

J. Schulz, R. Boyacio?lu, and D. G. Norris, Multiband multislab 3D time-of-flight magnetic resonance angiography for reduced acquisition time and improved sensitivity, Magn Reson Med, vol.75, issue.4, pp.1662-1668, 2016.

G. Vincent, A. Vignaud-alexandre, B. Alexis, B. Denis, and . Nicolas, Universal pulses: A new concept for calibration-free parallel transmission, Magn Reson Med, vol.77, issue.2, pp.635-643, 2016.

B. Nicolas, G. Vincent, A. Alexis, L. Michel, F. Guillaume et al., Workflow proposal for defining SAR safety margins in parallel transmission, In Proc. Intl. Soc. Mag. Reson. Med, vol.26, p.295, 2018.

G. Eichfelder and M. Gebhardt, Local specific absorption rate control for parallel transmission by virtual observation points, Magn Reson Med, vol.201, issue.5, pp.1468-76

A. Massire, M. A. Cloos, M. Luong, A. Amadon, A. Vignaud et al., Thermal simulations in the human head for high field MRI using parallel transmission, J Magn Reson Imaging, vol.35, issue.6, pp.1312-1333, 2012.

G. Ferrand, M. Luong, A. Amadon, A. Martijn, E. Cloos et al., Generalized Double-Acquisition Imaging for Radiofrequency Inhomogeneity Mitigation in High-Field MRI: Experimental Proof and Performance Analysis, vol.67, pp.175-182, 2012.

S. Max-local,

, Supplementary Information Table 1: Power and SAR estimates at the end of the spokes optimization (single spoke / double spoke) for every subject, in 2-slab and 3-slab configurations. Values in red indicate saturation of the associated constraints: almost in all cases