Wound-rotor synchronous machine dq modeling with saturation for transient analysis - CentraleSupélec Accéder directement au contenu
Communication Dans Un Congrès Année : 2017

Wound-rotor synchronous machine dq modeling with saturation for transient analysis

Résumé

In this paper, a nonlinear dq model is proposed for transient simulations of a salient-pole wound-rotor synchronous machine. Despite the nonlinearity between the flux linkage and the current, it is shown, thanks to a validation based on finite element simulations, that the new model is efficient for saturated transient state of the machine. This method allows obtaining more accurate results than classical linear dq model based on equivalent circuits or inductance matrices. This model is also more convenient than the linear dq model because it is more closely related to a physical model of the machine. Finally, it is far easier and faster to use than the finite element model in simulation and control.
Fichier non déposé

Dates et versions

hal-02413221 , version 1 (16-12-2019)

Identifiants

Citer

Teodor Wisniewski, Jean-Claude Vannier, Bruno Lorcet, Jacques Saint-Michel, Xavier Jannot. Wound-rotor synchronous machine dq modeling with saturation for transient analysis. 2017 IEEE International Electric Machines and Drives Conference (IEMDC), May 2017, Miami, United States. pp.1-6, ⟨10.1109/IEMDC.2017.8002063⟩. ⟨hal-02413221⟩
112 Consultations
0 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More