Cathode Surface Morphology Effects on Field Emission: Vacuum Breakdown Creation of Field Emitters - CentraleSupélec Accéder directement au contenu
Article Dans Une Revue IEEE Transactions on Plasma Science Année : 2014

Cathode Surface Morphology Effects on Field Emission: Vacuum Breakdown Creation of Field Emitters

Résumé

The effect of stainless steel cathode surface morphology on field electronic emission in high vacuum (~10⁻₅ Pa) is studied. The surface rugosity is shown to affect the emission intensity; high-aspect ratio surface features lead to locally enhanced electric field, thereby increasing the field electronic emission. A breakdown in the vacuum, caused either by impact of charged dust particles or other impurities, or by overheating and vaporization of field emitters, can lead to cratering on the cathode surface. This cratering drastically changes the local surface rugosity, enhancing the local field and leads to greater emission intensity. Treatment of the cathode surface by glow discharge at higher pressure is known to reduce field emission by ionic bombardment and sputtering of emission sites; an image of such a glow-type discharge in the same apparatus used to study field emission is presented.
Fichier non déposé

Dates et versions

hal-01073063 , version 1 (08-10-2014)

Identifiants

Citer

Khaled Almaksour, Michael Joseph Kirkpatrick, Emmanuel Odic, Philippe Dessante, Philippe Teste. Cathode Surface Morphology Effects on Field Emission: Vacuum Breakdown Creation of Field Emitters. IEEE Transactions on Plasma Science, 2014, 42 (10), pp.2582-2583. ⟨10.1109/TPS.2014.2319393⟩. ⟨hal-01073063⟩
99 Consultations
0 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More