Design Presentation and Induced-Stress Study of a 6-axis Single-Mass Piezoelectric IMU

Abstract : This paper explores steps towards induced stress enhancement of a new improved design of a 6-axis single-mass piezoelectric motion sensor. The detailed numerical analysis was based on a previously developed and validated finite element model for the new design. The experimental data, reported in literature for a design with a similar geometry, has been used in the validation. Using the same dimensions' range, we detail the new improved design geometry. The analysis of the induced stress in response to x, y and z-accelerations shows that the new design offers better performances. In response to x-axis and z-axis accelerations, evaluated induced stress values are 2 and 2.5 orders of magnitude higher than those measured on the reported design, respectively.
Document type :
Conference papers
Complete list of metadata

https://hal-centralesupelec.archives-ouvertes.fr/hal-02401755
Contributor : Amandine Lustrement Connect in order to contact the contributor
Submitted on : Tuesday, December 10, 2019 - 10:57:51 AM
Last modification on : Saturday, December 4, 2021 - 4:09:05 AM

Identifiers

Citation

Hela Almabrouk, Sinda Kaziz, Brahim Mezghani, Fares Tounsi, Yves Bernard. Design Presentation and Induced-Stress Study of a 6-axis Single-Mass Piezoelectric IMU. 2018 30th International Conference on Microelectronics (ICM), Dec 2018, Sousse, Tunisia. pp.144-147, ⟨10.1109/ICM.2018.8703989⟩. ⟨hal-02401755⟩