Skip to Main content Skip to Navigation
Journal articles

Development of an Anthropomorphic Phantom of the Axillary Region for Microwave Imaging Assessment

Abstract : We produced an anatomically and dielectrically realistic phantom of the axillary region to enable the experimental assessment of Axillary Lymph Node (ALN) imaging using microwave imaging technology. We segmented a thoracic Computed Tomography (CT) scan and created a computer-aided designed file containing the anatomical configuration of the axillary region. The phantom comprises five 3D-printed parts representing the main tissues of interest of the axillary region for the purpose of microwave imaging: fat, muscle, bone, ALNs, and lung. The phantom allows the experimental assessment of multiple anatomical configurations, by including ALNs of different size, shape, and number in several locations. Except for the bone mimicking organ, which is made of solid conductive polymer, we 3D-printed cavities to represent the fat, muscle, ALN, and lung and filled them with appropriate tissue-mimicking liquids. Existing studies about complex permittivity of ALNs have reported limitations. To address these, we measured the complex permittivity of both human and animal lymph nodes using the standard open-ended coaxial-probe technique, over the 0.5 GHz–8.5 GHz frequency band, thus extending current knowledge on dielectric properties of ALNs. Lastly, we numerically evaluated the effect of the polymer which constitutes the cavities of the phantom and compared it to the realistic axillary region. The results showed a maximum difference of 7 dB at 4 GHz in the electric field magnitude coupled to the tissues and a maximum of 10 dB difference in the ALN response. Our results showed that the phantom is a good representation of the axillary region and a viable tool for pre-clinical assessment of microwave imaging technology.
Document type :
Journal articles
Complete list of metadata

https://hal-centralesupelec.archives-ouvertes.fr/hal-03663634
Contributor : Nadine joachimowicz Connect in order to contact the contributor
Submitted on : Tuesday, May 10, 2022 - 12:14:59 PM
Last modification on : Wednesday, May 18, 2022 - 3:40:34 AM

File

Development_of_an_Anthropomorp...
Publisher files allowed on an open archive

Identifiers

Citation

Matteo Savazzi, Soroush Abedi, Niko Ištuk, N. Joachimowicz, Hélène Roussel, et al.. Development of an Anthropomorphic Phantom of the Axillary Region for Microwave Imaging Assessment. Sensors, MDPI, 2020, 20 (17), pp.4968. ⟨10.3390/s20174968⟩. ⟨hal-03663634⟩

Share

Metrics

Record views

13

Files downloads

2